This section describes the terminal flags and fields that control
parameters usually associated with asynchronous serial data
transmission. These flags may not make sense for other kinds of
terminal ports (such as a network connection pseudo-terminal). All of
these are contained in the c_cflag
member of the struct
termios
structure.
The c_cflag
member itself is an integer, and you change the flags
and fields using the operators &
, |
, and ^
. Don't
try to specify the entire value for c_cflag
—instead, change
only specific flags and leave the rest untouched (see Setting Modes).
If this bit is set, it indicates that the terminal is connected “locally” and that the modem status lines (such as carrier detect) should be ignored. On many systems if this bit is not set and you call
open
without theO_NONBLOCK
flag set,open
blocks until a modem connection is established.If this bit is not set and a modem disconnect is detected, a
SIGHUP
signal is sent to the controlling process group for the terminal (if it has one). Normally, this causes the process to exit; see Signal Handling. Reading from the terminal after a disconnect causes an end-of-file condition, and writing causes anEIO
error to be returned. The terminal device must be closed and reopened to clear the condition.
If this bit is set, a modem disconnect is generated when all processes that have the terminal device open have either closed the file or exited.
If this bit is set, input can be read from the terminal. Otherwise, input is discarded when it arrives.
If this bit is set, two stop bits are used. Otherwise, only one stop bit is used.
If this bit is set, generation and detection of a parity bit are enabled. See Input Modes, for information on how input parity errors are handled.
If this bit is not set, no parity bit is added to output characters, and input characters are not checked for correct parity.
This bit is only useful if
PARENB
is set. IfPARODD
is set, odd parity is used, otherwise even parity is used.
The control mode flags also includes a field for the number of bits per
character. You can use the CSIZE
macro as a mask to extract the
value, like this: settings.c_cflag & CSIZE
.
The following four bits are BSD extensions; this exist only on BSD systems and the GNU system.
If this bit is set, enable flow control of output based on the CTS wire (RS232 protocol).
If this bit is set, enable flow control of input based on the RTS wire (RS232 protocol).
If this bit is set, it says to ignore the control modes and line speed values entirely. This is only meaningful in a call to
tcsetattr
.The
c_cflag
member and the line speed values returned bycfgetispeed
andcfgetospeed
will be unaffected by the call.CIGNORE
is useful if you want to set all the software modes in the other members, but leave the hardware details inc_cflag
unchanged. (This is how theTCSASOFT
flag totcsettattr
works.)This bit is never set in the structure filled in by
tcgetattr
.